Finite differences for PDEs
Replace every derivative by a difference on a grid, and a PDE (Partial Differential Equation) becomes arithmetic a computer can do. The art is doing it stably.
Lay a grid over space and time. Store the temperature only at the grid points. Approximate each derivative using neighbouring values — a stencil. Now the PDE says how to compute the next row of the grid from the current one. Choose the time step carelessly, though, and tiny errors grow until the answer is garbage.
- finite difference formulas for $u_x$ and $u_{xx}$ and their truncation error;
- the explicit scheme for the heat equation and its stability limit $r \le \tfrac12$;
- von Neumann stability analysis and the CFL (Courant–Friedrichs–Lewy) condition;
- the Lax equivalence theorem: consistency + stability = convergence;
- how to measure the order of a PDE solver.
Take $u(x) = x^2$ at the three grid points $x = 0.9, 1, 1.1$ (spacing $h = 0.1$): the values are $0.81, 1, 1.21$. Then $$\underbrace{\frac{1.21 - 1}{0.1} = 2.1}_{\text{forward}},\qquad \underbrace{\frac{1.21 - 0.81}{0.2} = 2}_{\text{central}},\qquad \underbrace{\frac{0.81 - 2(1) + 1.21}{0.01} = 2}_{\text{second difference}}.$$ The exact values are $u'(1) = 2$ and $u''(1) = 2$. The forward difference is off by $h = 0.1$; the central differences are exact for any parabola. A finite difference method is nothing more than this, done at every grid point at once.
1. Grid and stencils
Use grid points $x_i = i\,\Delta x$ and times $t^n = n\,\Delta t$, and write $u_i^n \approx u(x_i, t^n)$. Taylor's theorem (Chapter 2) gives
| Derivative | Finite difference | Error |
|---|---|---|
| $u_t$ | $\dfrac{u_i^{n+1} - u_i^n}{\Delta t}$ (forward) | $O(\Delta t)$ |
| $u_x$ | $\dfrac{u_{i+1} - u_{i-1}}{2\Delta x}$ (central) | $O(\Delta x^2)$ |
| $u_x$ | $\dfrac{u_{i} - u_{i-1}}{\Delta x}$ (backward / upwind) | $O(\Delta x)$ |
| $u_{xx}$ | $\dfrac{u_{i-1} - 2u_i + u_{i+1}}{\Delta x^2}$ (central) | $O(\Delta x^2)$ |
| $\Delta u = u_{xx} + u_{yy}$ | $\dfrac{u_{i-1,j} + u_{i+1,j} + u_{i,j-1} + u_{i,j+1} - 4u_{i,j}}{h^2}$ (5-point) | $O(h^2)$ |
If $u$ has four continuous derivatives, $$\frac{u(x - h) - 2u(x) + u(x + h)}{h^2} = u''(x) + \frac{h^2}{12}u^{(4)}(\xi), \quad \xi \in (x - h, x + h).$$
LeVeque, Finite Difference Methods for Ordinary and Partial Differential Equations, SIAM (2007), chapter 1 "Finite Difference Approximations".2. The explicit scheme for the heat equation

For $u_t = \alpha u_{xx}$, use forward difference in time and central in space (FTCS (Forward-Time, Central-Space scheme)): $$\frac{u_i^{n+1} - u_i^n}{\Delta t} = \alpha\,\frac{u_{i-1}^n - 2u_i^n + u_{i+1}^n}{\Delta x^2} \quad\Longrightarrow\quad u_i^{n+1} = u_i^n + r\,\big(u_{i-1}^n - 2u_i^n + u_{i+1}^n\big),\qquad r = \frac{\alpha\,\Delta t}{\Delta x^2}.$$ Each new value is computed from three old ones — the stencil. Everything depends on the single number $r$.
3. Why ½? von Neumann stability analysis
Errors on the grid can be written as a sum of Fourier modes $e^{\mathrm i k x_i}$. Insert a single mode $u_i^n = G^n e^{\mathrm i k i\Delta x}$ into the scheme. Using $e^{\mathrm i\theta} + e^{-\mathrm i\theta} - 2 = -4\sin^2(\theta/2)$: $$G = 1 - 4r\sin^2\!\Big(\frac{k\Delta x}{2}\Big).$$ Each step multiplies the mode by the amplification factor $G$. Stability needs $|G| \le 1$ for every $k$. The worst mode is the saw-tooth ($\sin^2 = 1$): $|1 - 4r| \le 1 \iff r \le \tfrac12$. That is exactly the saw-tooth you saw blow up.
A linear constant-coefficient scheme on a periodic grid is stable (in the $\ell^2$ norm) if its amplification factor satisfies $|G(k)| \le 1 + C\Delta t$ for all wave numbers $k$.
Charney, Fjørtoft & von Neumann, "Numerical integration of the barotropic vorticity equation", Tellus 2 (1950) 237–254; Strikwerda, Finite Difference Schemes and Partial Differential Equations, 2nd ed., SIAM (2004), chapter 2; LeVeque (2007), chapter 9.Averaging the spatial difference between times $n$ and $n+1$ gives the Crank–Nicolson scheme, second order in time and stable for every $r$: $$\frac{u_i^{n+1} - u_i^n}{\Delta t} = \frac{\alpha}{2}\left[\delta^2 u_i^{n} + \delta^2 u_i^{n+1}\right], \qquad \delta^2 u_i = \frac{u_{i-1} - 2u_i + u_{i+1}}{\Delta x^2}.$$ Each step now requires solving a tridiagonal linear system (Chapter 4) — cheap, $O(N)$ operations.
Crank & Nicolson, "A practical method for numerical evaluation of solutions of partial differential equations of the heat-conduction type", Proc. Camb. Phil. Soc. 43 (1947) 50–67.4. Waves and the CFL condition
For the advection equation $u_t + a\,u_x = 0$ ($a > 0$), a bump travels right at speed $a$. The upwind scheme uses the backward difference (information comes from the left): $$u_i^{n+1} = u_i^n - \nu\,\big(u_i^n - u_{i-1}^n\big), \qquad \nu = \frac{a\,\Delta t}{\Delta x}\ \ (\text{Courant number}).$$
A necessary condition for convergence of an explicit scheme is that its numerical domain of dependence contains the true domain of dependence of the PDE. For upwind advection this means $$\nu = \frac{|a|\,\Delta t}{\Delta x} \le 1:$$ in one time step, the wave must not travel further than one grid cell.
Courant, Friedrichs & Lewy, "Über die partiellen Differenzengleichungen der mathematischen Physik", Mathematische Annalen 100 (1928) 32–74; LeVeque (2007), chapter 10.5. Convergence: the Lax equivalence theorem
For a consistent finite difference approximation of a well-posed linear initial value problem, stability is necessary and sufficient for convergence.
Lax & Richtmyer, "Survey of the stability of linear finite difference equations", Comm. Pure Appl. Math. 9 (1956) 267–293.This is the PDE version of Dahlquist's theorem for ODEs (Chapter 6). Consistency (small local error) is usually easy to check with Taylor series; stability is the hard part, and von Neumann analysis checks it.
For steady problems the recipe is the same: discretise $-u'' = f$ with the central difference, solve the tridiagonal system, and the error is $O(h^2)$. Measure it:
For complex geometries, engineers use the finite element method (FEM: approximate $u$ by piecewise polynomials and impose the PDE in an averaged, "weak" sense) and the finite volume method (FVM: conserve fluxes across cell faces — the standard in reservoir and CFD codes). The ideas of consistency, stability and convergence carry over unchanged.
Brenner & Scott, The Mathematical Theory of Finite Element Methods, 3rd ed., Springer (2008); LeVeque, Finite Volume Methods for Hyperbolic Problems, CUP (2002).A stencil applied across a grid is a convolution: the 5-point Laplacian is a $3\times3$ convolution kernel. Convolutional networks can therefore represent — and learn — finite difference operators (Long, Lu, Ma & Dong, "PDE-Net", ICML 2018). Classical solvers also generate the training data for neural operators, and remain the reference against which every SciML method must be checked.
6. Try it in Python
import numpy as np
import matplotlib.pyplot as plt
def ftcs(N=20, r=0.45, steps=100):
x = np.linspace(0, 1, N + 1); dx = 1 / N
u = np.minimum(x, 1 - x) * 2 # triangle, u = 0 at both ends
for _ in range(steps):
u[1:-1] = u[1:-1] + r * (u[:-2] - 2 * u[1:-1] + u[2:])
return x, u, steps * r * dx**2 # final time t = n * dt
for r in [0.45, 0.52]:
x, u, t = ftcs(r=r, steps=120)
plt.plot(x, u, "o-", label=f"r = {r}, t = {t:.3f}")
plt.ylim(-1, 1.2); plt.legend(); plt.grid(alpha=.3); plt.title("FTCS: stable vs unstable")
plt.show()
With FTCS for the heat equation you halve $\Delta x$. To stay stable, $\Delta t$ must be…
Right: $r = \alpha\Delta t/\Delta x^2 \le \tfrac12$, so $\Delta t \propto \Delta x^2$.
Upwind scheme, wave speed $a = 2$, $\Delta x = 0.01$. The largest stable $\Delta t$ is…
Right: CFL needs $2\,\Delta t/0.01 \le 1$, so $\Delta t \le 0.005$.
Grids grow like $n^d$ with dimension, stability restricts time steps, complex geometries need meshes, and measured data cannot easily be added to a scheme. Chapter 9 looks at these limits honestly, and at how SciML methods address them by building on what you learned here. Go to Chapter 9 →
- Stencils replace derivatives; Taylor series give their order of accuracy.
- FTCS for heat is stable iff $r = \alpha\Delta t/\Delta x^2 \le \tfrac12$ (von Neumann).
- Explicit schemes for waves obey the CFL condition $|a|\Delta t/\Delta x \le 1$.
- Lax: consistency + stability ⇔ convergence.
- Always verify a solver by measuring its order on a problem with known solution.
Further reading
- R. J. LeVeque, Finite Difference Methods for Ordinary and Partial Differential Equations, SIAM, 2007.
- J. C. Strikwerda, Finite Difference Schemes and Partial Differential Equations, 2nd ed., SIAM, 2004.
- K. W. Morton & D. F. Mayers, Numerical Solution of Partial Differential Equations, 2nd ed., Cambridge University Press, 2005.
- G. D. Smith, Numerical Solution of Partial Differential Equations: Finite Difference Methods, 3rd ed., Oxford University Press, 1985.